Section 2 INSTALLATION & CONNECTION
ZFV
User’s Manual
Section 2
Amplifier Unit
Timing charts
The following shows the timing charts when communication is performed with external
devices.
Measurement
Continuous measurement
Measurement is performed continuously for the duration that the TRIG signal is ON.
The measurement result is updated, and output to external devices at each measure-
ment cycle.
Synchronous measurement
Measurement is performed only once in synchronous with the change in TRIG signal
state from OFF to ON, and the result is output.
The minimum ON width of the TRIG signal is 1 ms.
The OUTPUT signal is held until the next measurement result is updated.
Note, however, that when one-shot output is currently set, the OUTPUT signal is held
for the preset time.
One-shot output p.61
Tout
TRIG
OUTPUT
ENABLE
OFF
ON
OFF
ON
OFF
ON
Tout: Measurement cycle
The measurement cycle changes
depending on the setting.
Tout
TRIG
OUTPUT
ENABLE
OFF
ON
OFF
ON
OFF
ON
Tout: Measurement time.
The measurement time changes
depending on the setting.