80
Section 4 APPENDIX
ZFV
User’s Manual
Section 4
Q&A
Q&A
Question Answer
Can I turn LED light emission of the Sensor
Head OFF?
Yes, you can.
[CUSTM]-[Set LIGHT] to [0000].
p.65
What should I do to set the measurement
time as short as possible?
There are two ways of setting a shorter measurement time:
[Set CUSTM]-[IMAGE RATE] to [HIGH SPEED]. Note, however,
that image processing becomes rougher, and measurement
accuracy drops.
p.59
Switch the screen display during measurement to “Display only
image”.
The measurement time can be reduced proportionate to the
reduction in display time.
p.57
Teaching is not going well. What should I
do?
Workpiece move teaching mode
A probable cause is that the workpiece is not properly in the
teaching area as intended.
Change to the workpiece stop teaching mode or teaching by key
operation.
A probable cause is that teaching is not successful because an
image is too dark or too bright.
Adjust light emission at [CUSTM]-[LIGHT] so that the workpiece
is projected clearly, and execute teaching again.
p.65