E.2 InfiniBand Network Cabling Tables
This section contains the tables for the InfiniBand network cabling. The Sun Network
QDR InfiniBand Gateway Switch is located in located in rack units 26, 24, 23, or 16
(depending on the rack configuration).
This section contains the following topics:
• Exalogic Machine Full Rack
• Exalogic Machine Half Rack
• Exalogic Machine Quarter Rack
• Exalogic Machine Eighth Rack
E.2.1 Exalogic Machine Full Rack
This section contains the following tables:
• Table E-5
• Table E-6
• Table E-7
Table E-5 lists the location, ports and cables for the InfiniBand connections for an
Exalogic machine full rack.
Table E-5 InfiniBand Network Cabling for Exalogic Machine Full Rack
From
Rack Unit
(Sun
Network
QDR
InfiniBand
Gateway
Switch)
Port To Rack
Unit
Type of
Equipment
Port Description
U26 9A U42 Compute node PCIe 2, P1 3 meter QDR
InfiniBand cable
U26 9B U41 Compute node PCIe 2, P1 3 meter QDR
InfiniBand cable
U26 10A U40 Compute node PCIe 2, P1 3 meter QDR
InfiniBand cable
U26 10B U39 Compute node PCIe 2, P1 3 meter QDR
InfiniBand cable
U26 11A U38 Compute node PCIe 2, P1 3 meter QDR
InfiniBand cable
U26 11B U37 Compute node PCIe 2, P1 2 meter QDR
InfiniBand cable
InfiniBand Network Cabling Tables
Cabling Tables E-7