73
English
Control settings
Sets each item of the function which enables to control
multiple displays at the same time, or individually.
[Control settings] - submenu screen
Control settings
Serial response(ID all)
Off
Display ID
Controller ID function Off
Serial ID function Off
Serial response (Normal)
On
■ [Display ID]
Set ID number when controlling the Display with
[Controller ID function] and [Serial ID function].
0 to 100 (Standard value: 0)
■ [Controller ID function]
Enables/disables the [Controller ID function].
[Off]:
Disables the [Controller ID function]. (Can be
operated as normal remote control.)
[On]:
Enables the [Controller ID function]. Effective on
switching to [On].
Note
●
To use the [Controller ID function], setting ID
numbers both for the remote control and for the
display unit is required.
For ID number setting for the remote control, see
page 116.
●
About how to reset the settings to defaults, refer to
“Initialization” (see page 121).
■ [Serial ID function]
Set to control external control with the PC connected to
SERIAL terminal according to the Display’s ID number.
[Off]:
Disables external control by the ID.
[On]:
Enables the external control by the ID.
■ [Serial response (Normal)]
Sets whether to send the response command to normal
commands without ID.
[Off]:
Does not respond. (Including the inquiry command)
[On]:
Responds.
■ [Serial response(ID all)]
Set whether to respond to the command or not, when
serial command of ID number “0” is received.
[Off]:
Does not respond.
[On]:
Responds.
Information timing
Set up the informing manner for no signal or
temperature rising.
During RS-232C controls:
Warning or error message sent from the display
automatically.
During LAN controls:
Acquire the warning or error message from the
display.
[Information timing] - submenu screen
Information timing
No signal warning
No signal warning timing
Temperature warning
No signal error
No signal error timing
On
5min
On
10min
On
[No signal warning]
When set to [On], the display sends out the no signal
warning.
[No signal warning timing]
Set up the detecting time for no signal warning.
(Range:01‒60,Interval:1minute)
[No signal error]
When set to [On], the display sends out the no signal
error.
[No signal error timing]
Set up the detecting time for no signal error.
(Range:01‒90,Interval:1minute)
●
The warning of [No signal warning] and the error
of [No signal error] are not sent when the no signal
state is detected through any of the following
functions:
[No signal power off], [HDMI1 power management],
[HDMI2 power management], [DVI-D power
management], [PC power management] (see page
57)
Setting Example:
●
If there is no signal when [PC IN] is input, [PC
power management] is activated first and the
Display enters the standby mode.
[No signal warning timing]: 5 minutes
[No signal error timing]: 10 minutes
[PC power management]: [On] (60 seconds)