ELECTRICAL SYSTEMS
8.152004 Four Stroke PWC Service Manual
Starter Motor -- Disassembly -- Contin u ed
5. Measure resistance between starter input terminal and
insulated brushes. Reading should be .3 ohms
or less. Remember to subtract meter lead resistance.
6. Measure resistance between insulated brush and
starter housing. Reading should be infinite. (OL).
Inspect insulation on brush wires for damage and
repair or replace as necessary.
7. Slide positive brush springs to the side, pull brushes
out of their guides and remove brush plate. Slide brush
end frame off end of starter. NOTE: The electrical
input post must stay with the field coil housing.
8. Measure resistance between ground brush and brush
plate. Resistance should be .3 ohms or less.