Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 120
fb_safe_mode_atten
Safe Mode Attenuation For Feedback Reduction
Description
This parameter defines the maximum amount of attenuation (in dB) applied to
the input if all the filters are used up and the feedback reduction algorithm
continues to detect singing. Setting this parameter to 0 dB means that no atten-
uation is performed even if all the filters are used up.
mic_source_index
Select Mic audio Source Index
Argument Argument value
Channel Type Virtual Channel
Value Type Floating-Point
Read/Write Mode Read/Write
Phys Chans Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans Mono, Stereo
System Limits Minimum: 0.0, Maximum: 100.0, Resolution: 0.1
Default 3.0
User Limits
Supported
No
Event Source No
Argument Argument value
Channel Type Virtual Channel
Value Type Sequence
Read/Write Mode Read/Write
Phys Chans Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans Mono, Stereo
Indices 1-32 : Physical channel
System Limits Minimum: 1, Maximum: 15
Default 1
Event Source No

Table of Contents

Other manuals for Polycom SoundStructure C8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom SoundStructure C8 and is the answer not in the manual?

Polycom SoundStructure C8 Specifications

General IconGeneral
BrandPolycom
ModelSoundStructure C8
CategoryConference System
LanguageEnglish

Related product manuals