Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 124
Description
This parameter sets the gain of the signal produced by the signal generator, in
dB. A gain of 0 dB will produce a signal that has the same RMS level as a sine
wave at -20 dBFS (the nominal signal level). This means that not all signal
types will have the same peak level, and some types may clip before a gain of
20 dB is applied.
sig_gen_sweep_start
Signal Generator Sweep Start Frequency
Description
When the signal generator’s sig_gen_type is set to sweep, this parameter sets
the frequency (in Hz) at which the sweep generator begins. The direction of the
frequency sweep will be up or down depending on whether this parameter is
higher or lower than the sig_gen_sweep_stop parameter.
sig_gen_sweep_step
Signal Generator Sweep Step Size
Argument Argument value
Channel Type Virtual Channel
Value Type Floating-Point
Read/Write Mode Read/Write
Phys Chans Signal Generator
Virt Chans Mono
System Limits Minimum: 20.0, Maximum: 20000.0, Resolution: 0.1
Default 20.0
User Limits
Supported
No
Event Source No
Argument Argument value
Channel Type Virtual Channel
Value Type List
Read/Write Mode Read/Write
Phys Chans Signal Generator