Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 126
sig_gen_sweep_time
Signal Generator Sweep Time
Description
When the signal generator’s sig_gen_type is set to sweep, this parameter sets
the duration (in milliseconds) that the sweep generator takes to sweep from its
start frequency to its stop frequency.
sig_gen_tone_freq
Signal Generator Tone Frequency
Description
This parameter sets the frequency (in Hz) of the sine wave produced by the
signal generator when its sig_gen_type is set to tone.
Argument Argument value
Channel Type Virtual Channel
Value Type Integer
Read/Write Mode Read/Write
Phys Chans Signal Generator
Virt Chans Mono
System Limits Minimum: 10, Maximum: 60000
Default 10000
User Limits
Supported
No
Event Source No
Argument Argument value
Channel Type Virtual Channel
Value Type Floating-Point
Read/Write Mode Read/Write
Phys Chans Signal Generator
Virt Chans Mono
System Limits Minimum: 20.0, Maximum: 20000.0, Resolution: 0.1
Default 1000.0
User Limits
Supported
No
Event Source No