Home
Pyronix
Security System
PCX 78
Pyronix PCX 78 User Manual
4
of 1
of 1 rating
100 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Pr
o
g
ram
T
imers
CHANGE CODES?
t
t
t
t
t
t
t
t
t
t
t
x
t
t
x
x
x
x
t
t
t
t
t
t
t
t
t
t
x
x
x
x
x
t
x
x
x
x
x
x
x
x
x
x
x
x
x
x
b
x
WLS
=
Wi
re
l
ess
NA
T = Non A
c
t
ivity
Timer
C
o
nf
=
Con
f
i
rm
S
u
per
vn =
Wi
re
l
ess
Sup
ervi
s
i
on
Time
B
u
r
g
l
r = Bu
r
g
l
a
ry
0-255
Sec
onds
0-255
Sec
onds
0-255
Sec
onds
2-15 Minutes
0-20 Minutes
0-99 Minutes
0-250
Minu
t
e
s
0-9
Times
t
x
0-99 Minutes
Ex
it Suspnd
Time
En
try Comm Delay
0-180
Sec
onds
0-199
Sec
onds
x
t
t
A
rea
s 0123A
BCD
PROGRAM
TIMER
S?
A En
try Time 1
A En
try Time 2
A Exit
Time
A Be
ll
Time
A APP Exit
Time
Rep
eat for all areas
Stro
be
Time
Be
ll Delay
Number R
e
-arms
[3]
AC M
issing Delay
AC F
ail D
e
lay
0-250
Minu
t
e
s
Fi
nal Door Delay
0-255
Sec
onds
Dou
ble Knoc
k
0-75 Seconds
L
ine F
ault Delay
0-250
Sec
onds
Arm
F
ail
Time
0-255
Sec
onds
Gua
rd Code Delay
0-10 Minutes
Fi
re Bell
Time
0-99 Minutes
Arm
F
ail W
arning
NA
T
Hours
Timer
0-23 Hours
NA
T
Day
Timer
0-14 Days
Pu
lsd Burglr Any
0-255
Sec
onds
WL
S Supervn Time
0-99 Hours
WL
S J
a
mming
Time
0-100
Sec
onds
Se
r
v
ice
Timer
0-365
Day
s
Seconds [030]
Seconds [030]
Seconds [030]
Seconds [005]
Minutes [03]
Minutes [00]
Minutes [00]
Minutes [000]
Minutes [005]
Seconds [005]
Seconds [10]
Seconds [000]
Seconds [000]
Seconds [250]
Seconds [220]
Minutes [03]
Minutes [99]
Minutes [00]
Days [00]
Hours [00]
Seconds [005]
Hours [02]
Seconds [100]
Days [000]
PC
X
I
nst
a
l
lati
on
Gui
d
e
10201
7852
-
V
01
43
42
44
Table of Contents
Table of Contents
3
System Description
5
Introduction
5
Homecontrol+ App
6
System Overview
7
Using the Keypad on the PCX
9
Important Installation Notes
11
Overview of Devices
12
RS-485 Wiring
13
Input Mapping Overview
14
Output Mapping Overview
15
Setting up
15
The Printed Circuit Board
17
Power and Battery Connections for the PCX S
18
Power and Battery Connections for the PCX L
20
Connecting Peripherals
21
Input Connections
21
Output (PGM) Connections
23
External Sounder Connections
25
Modems
27
Connecting Modems
28
PSTN Modem (DIGI-1200)
28
GPRS Modem (DIGI-GPRS)
29
LAN Modem (DIGI-LAN)
30
Wi-Fi Modem (DIGI-WIFI/XA)
30
Connecting to the Upload/Download Software
30
Serial Connection (RS232)
31
Pyronixcloud Connection
32
Configuration
33
The Engineer Menu
33
Navigating in the Engineer and User Menus
33
Main Menus and Sub Menus
33
Entering the Engineer Menu
35
Accessing the Engineer Menu on any External Wired Keypad
35
Date & Time
36
Learn Wireless Devices
37
Program Inputs
38
Program EOL
39
Install Rixs
40
Program Outputs
41
Install Keypads/Readers
42
Program Timers
43
Change Codes
44
Volume Control
45
System Options
46
System Displays and Exit Options
47
Review Logs
48
Engineer Tests
49
Diagnostics
50
Wireless Devices
50
Wired Devices
51
Communications (DIGI-GPRS)
52
Communications (DIGI-1200)
53
Communications (DIGI-LAN)
54
Communications (DIGI-WIFI/XA)
55
Engineer Restore Options
56
Communications
57
App Set-Up (Standard Security)
58
App Set-Up (High Security)
59
Network Set-Up
60
ARC Signalling
61
User SMS Signalling
62
Advanced Communications
63
Alarm Responses
64
Options Up/Downloading
65
Download by Cloud (Standard Security)
66
Download by Cloud (High Security)
67
Download by Serial Comm
68
Software Revision
68
Factory Default
69
Exiting the Engineer Menu
70
Standalone Wired Keypad
71
Technical Specifications
72
Communication Loom
74
Troubleshooting
76
Device Fail / Active Faults
76
System Faults and Troubleshooting
76
Support Contact Details
79
Reference
80
Handover Form
80
EN 50131 Terminology
80
Input Types
81
Output Types
82
Time Inputs
86
SMS Commands
88
Event Types
89
General Event Types
89
SIA and Contact ID Codes
90
Access Levels
95
Compliance
96
Notes
97
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Pyronix PCX 78 and is the answer not in the manual?
Ask a question
Pyronix PCX 78 Specifications
General
Wired zones
8
Partitions
4
Weight
2.5kg
Type
Hybrid Alarm Control Panel
Wireless zones
70
Inputs
8
Operating Temperature
-10°C to +50°C
Related product manuals
Pyronix PCX 46
32 pages
Pyronix Paragon Plus
10 pages
Pyronix 256
168 pages
Pyronix Enforcer
28 pages
Pyronix XDL12TT-AM
2 pages
Pyronix Matrix 424
63 pages
Pyronix Deltabell E
2 pages
Pyronix ENFORCER V11
40 pages
Pyronix Enforcer V10
24 pages
Pyronix Enforcer 32-WE
36 pages
Pyronix ENFORCER Series
44 pages
Pyronix Wireless KF4-WE
28 pages