Event
SIA
code
CID
code
Event
Type
Number
Default 1
(ARC) Full
Reporting
Default 2
(ARC) No
Arm/Disarm
Default 3 (ARC) No
Arm/Disarm and
Alarm Restorals
Default
(SMS)
SPECIAL LOG
Zone Special Log
Opened
UA 1146 28
û û û û
Zone Special Log
Closed
UR 3146 28
Zone Special Log
Switcher Opened
UA 1146 28
Zone Special Log
Switcher Closed
UR 3146 28
ALARM SILENCED
Alarm Silenced OR 1406 29
û ü û û
Sub-Area Alarm
Silenced
OG 1402 29
TECHNICAL ALARM SILENCED
Technical Alarm
Silenced
OR 1406 30
û û û û
Technical Alarm
in Sub-Area
Silenced
OG 1402 30
INFORMATION
Engineer Access LB 1627 31
û û û û
Engineer Exit LX 1628 31
System Restart 1305 31
Logs Cleared 1621 31
Engineer Reset RN 3313 31
Clean Started 1305 31
Site Changed YG 1306 31
Logs Nearly Full 1623 31
Input Walk
Tested
1607 31
Access Levels
Level Description
1 Access by any person; for example the general public.
2 User access by an operator; for example customers (systems users).
3 User access by an engineer; for example an alarm company professional.
4 User access by the manufacturer of the equipment.
PCX Installation Guide 102017852 - V01 95