No. Time Input No. Time Input No. Time Input
50 Georgetown -4 103 Muscat 4 156 Yangon Rangu 6.5
51 Greenland -3 104 Nairobi 3 157 Yerevan 4
52 Guadalajara -6 105 New Caledonia 11 158 Zagreb 1
SMS Commands
All SMS commands must start with a valid User Code and are not case sensitive unless the
utilised outputs are activated. If an SMS command is not recognised, the panel will send an
‘incorrect command’ message back to you.
Example SMS command send Description Example SMS command
response
Arming via SMS text command
1234 Arm 0 1234 = User Code. Arm 0 = Will arm in
Areas 0
Final Arm; Area 0
1234 Arm ABCD0123 1234 = User Code. Arm ABCD0123 = Will
arm in Areas ABCD0123
Final Arm; Area ABCD0123
NOTE: If no areas are specified then all areas will arm (default).
Disarming via SMS text command
1234 Disarm 0
1234 = User Code. Disarm 0 = Will disarm
in Area 0
Disarm; Area 0
1234 Disarm ABCD0123 1234 = User Code. Disarm ABCD0123 =
Will disarm in Areas ABCD0123.
Disarm; Area ABCD0123
NOTE: If no areas are specified then all areas will disarm (default).
Arming with inputs bypassed via SMS text command
1234 Arm 0 Bypass 4
1234 = User Code. Arm 0 Bypass 4 = Arms
Area 0 and will bypass Input 4
Input Bypass; Area 0 Input 04
Force Arm: Area 0
1234 Arm 0 Bypass Kitchen 1234 = User Code. Arm 0 Bypass Kitchen =
Arms Area 0 and will bypass the Input
named Kitchen.
Input Bypass; Area 0 Kitchen
Force Arm: Area 0
Bypassing inputs via SMS text command
1234 Bypass 6
1234 = User Code. Bypass 6 = In the next
arming procedure, Input 6 will be
bypassed.
Input Bypass; Area 0 Input 06
1234 Bypass Garage 1234 = User Code. Bypass Garage = In the
next arming procedure, and will bypass the
Input named Garage.
Input Bypass; Area 0 Garage
NOTE: Output names have to be one word and spelled exactly as written in the panel e.g. Garage Door is not acceptable. It has
to be written as Garage-Door in the panel and the respective command will be Garage-Door.
88 PCX Installation Guide 102017852 - V01