RIGOL Chapter 2 Command System
2-152 MSO7000/DS7000 Programming Guide
 VSCale3: press down the vertical scale knob of CH3, i.g. switch the vertical scale of
CH3 to "Coarse" or "Fine".
 VSCale4: press down the vertical scale knob of CH4, i.g. switch the vertical scale of
CH4 to "Coarse" or "Fine".
 WSCale: press down the vertical scale knob in the waveform control area.
 WPOSition: press down the vertical position knob in the waveform control area.
 HSCale: press down the horizontal time base adjustment knob, i.g. enable or disable
the delayed sweep.
 HPOSition: press down the horizontal position knob, i.g. set the horizontal position to
0.
 HMENu: press the MENU key in the horizontal control area.
 KFUNction: press down the multifunction knob.
 TLEVel: press down the trigger level adjustment knob, i.g. set the trigger level to 0.
 TMENu: press the MENU key in the trigger control area.
 TMODe: press the MODE key in the trigger control area.
 RSTop: press the RUN/STOP key.
Example
:SYSTem:KEY:PRESs <CH1>/*Press the CH1 key on the front panel of the oscilloscope.*/
:SYSTem:KEY:INCRease
:SYSTem:KEY:DECRease
Syntax
:SYSTem:KEY:INCRease <key>[,<val>]
:SYSTem:KEY:DECRease <key>[,<val>]
Description
Rotate the specified knob clockwise.
Rotate the specified knob counterclockwise.
Parameter
Name
Type
Range
Default
<key>
Discrete
{VOFFset1|VOFFset2|VOFFset3|VOFFset4|
VSCale1|VSCale2|VSCale3|VSCale4|HSCale|
HPOSition|KFUNction|TLEVel|WVOLt|WPOSiti
on}
——
<val>
Integer
Determined by the range of the parameter
<key> and the current setting of the
parameter.
1
Remarks
 The value of the parameter <key> corresponds to the specified knob on the front
panel. The definitions for the knob are as follows:
VOFFset1: the CH1 vertical offset knob.
VOFFset2: the CH2 vertical offset knob.
VOFFset3: the CH3 vertical offset knob.
VOFFset4: the CH4 vertical offset knob.
VSCale1: the vertical scale knob of CH1.
VSCale2: the vertical scale adjustment knob of CH2.
VSCale3: the vertical scale adjustment knob of CH3.
VSCale4: the vertical scale adjustment knob of CH4.
HSCale: the horizontal time base adjustment knob.
HPOSition: the horizontal position adjustment knob.
KFUNction: the multifunction knob.

Table of Contents

Other manuals for Rigol DS7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS7000 Series and is the answer not in the manual?

Rigol DS7000 Series Specifications

General IconGeneral
BrandRigol
ModelDS7000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals