Chapter 2 Command System RIGOL
MSO7000/DS7000 Programming Guide 2-3
:SINGle
:SINGle
Sets the trigger mode of the oscilloscope to "Single". This command functions the same as
either of the following two operation: press SINGLE on the front panel; or send
the :TRIGger:SWEep SINGle command.
 In the single trigger mode, the oscilloscope performs a single trigger when the trigger
conditions are met and then it stops.
 When the waveform recording function is enabled or the recorded waveforms are
played back, this command is invalid.
 For the single trigger, you can use the :TFORce command to generate one trigger by
force.
:TFORce
:TFORce
Generates a trigger signal forcefully. This command is only applicable to the normal and
single trigger modes (refer to the :TRIGger:SWEep command). This command functions
the same as the FORCE key in the trigger control area of the front panel.