Page #15 background imageLoading...
Page #15 background image
15
Recording Knob Movements at Steps (Motion)
Recording/Playing MOTION
When “INST REC” is “ON, movements of the instrument’s [TUNE] knob,
[DECAY] knob, and [CTRL] knob are recorded in the steps.
If you hold down the [SHIFT] button and press the [VARIATION] button
to turn MOTION “ON, the recorded knob movements are played.
* REVERB LEVEL, DELAY LEVEL, MASTER FX CTRL, and MASTER FX ON are
also recorded/played according to the MOTION status.
MOTION setting
1. Hold down the [SHIFT] button and press the
[VARIATION] button.
2. Use the [VALUE] knob to select “ON.
Select “OFF” if you don’t want to record or play back motion data.
3. Press the [EXIT] button.
Entering a value at a specified step
While the [TR-REC] button is lit, you can specify a step and enter a
value for a knob.
1. Operate a knob while holding down a pad [1][16].
MEMO
Alternatively, you can hold down a pad [1]–[16] and use the
[UTILITY] (+) button and [COPY] (-) button to select the parameter
that you want to enter, and then use the [VALUE] knob to make
adjustments.
Clearing Motion Data of a Selected Target
1. While holding down the [SHIFT] button and the
[VARIATION] button, turn the [VALUE] knob to
select the target for deletion, and then press the
[VALUE] knob.
When you release your hand from the buttons, you return to the
previous screen.
Target to clear Explanation
ALL
All motion data is cleared.
VARIATION A–H
Variation motion data is cleared.
FILL IN 1, 2
FILL IN 1 and 2 motion data is cleared.
REVERB LEVEL
REVERB LEVEL motion data is cleared.
DELAY LEVEL
DELAY LEVEL motion data is cleared.
DELAY TIME
DELAY TIME motion data is cleared.
DELAY FEEDBACK
DELAY FEEDBACK motion data is cleared.
MASTER SW
MASTER SW motion data is cleared.
MASTER CTRL
MASTER CTRL motion data is cleared.
Clearing motion data for only a specific knob
This clears all motion data of a knob recorded in the track that’s
specified by the variation selected for playback.
1. While holding down the [SHIFT] button and the
[VARIATION] button, operate the knob.
Clearing motion data for a specific step
While the [TR-REC] button is lit, you can specify a step and clear the
knob values.
1. Long-press the pad [1][16] whose step contains the
motion data that you want to clear.
The MOTION/VELOCITY input screen appears.
2. While holding down the pad that you pressed in
step 1, press the [COPY] or [UTILITY] button to
select the motion that you want to clear.
* If the selected step (pad) does not contain motion data, “----” is shown as
the value.
* In this state, you can also turn the [VALUE] knob to input motion data.
3. While holding down the pad that you pressed in
step 1, press the [CLEAR] button.
Clearing the motion data of the specified step (pad).

Table of Contents

Other manuals for Roland TR-6S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roland TR-6S and is the answer not in the manual?

Roland TR-6S Specifications

Power IconPower
current draw500 mA
battery capacity1, 900 mAh
Battery IconBattery
ni-mh battery configurationAA, HR6 x 4
alkaline battery configurationAA, LR6 x 4
ni-mh battery lifeApproximately 5.5 hours
alkaline battery lifeApprox. 4.5 hours
Weight and Dimensions IconWeight and Dimensions
dimensions224 (W) x 132 (D) x 61 (H) mm
dimensions (inches)8-13/16 (W) x 5-3/16 (D) x 2-3/8 (H)
weight (including batteries)705 g
weight (including batteries in pounds)1 lb 9 oz