6.2) Temperature- and pressure observation
Engines of the 912 Series and 914 Series are equipped with two tempera-
ture control points on the cylinder heads for the coolant, one temperature
control point for the oil temperature and a pressure control point for the oil
pressure.
On engines of the 914 Series: The engine is also equipped with control
points for measurement of the airbox pressure, airbox temperature and the
ambient pressure.