Forced defrost operation
ـ Forced defrost operation : Is operation when Frost Formation occurs in the outdoor. (When carried out the service)
غ
Forced oil recovery operation
ـ Forced oil recovery operation : Oil recovery in the outdoor unit for the purpose of moving, installation if necessary.
Method of EntryK2 Tact Switch 6 times
Start pattern Heating commissioning pattern
Defrost start Defrost start : It is after 10 minutes which Safety Start finishes.
Defrost off General defrost operation conditions are the same as.
Etc. Defrost shut down and stop the normal pattern of the outdoor unit stop.
Method of EntryK2 Tact Switch 7 times
Start pattern Outdoor temperature is more than 10°C : Cooling c ommissioning
Outdoor temperature is less than 10°C : Heating c ommissioning
Oil recovery start Oil recovery start : It is after 10 minutes which Safety Start finishes.
Etc. Oil recovery shut down and
stop the normal pattern of the outdoor unit stop.
4-2-2 DVM S Models EEPROM Code Table
No. Model Name EEP Code
1
AM080FXVAGH/TK DB82-01358A
2 AM100FXVAGH/TK DB82-01359A
3 AM120FXVAGH/TK DB82-01360A
4AM140FXVAGH/TK DB82-01361A
5 AM160FXVAGH/TK DB82-01362A
6AM180FXVAGH/TK DB82-01363A
7 AM200FXVAGH/TK DB82-01364A
8AM220FXVAGH/TK DB82-01365A
9AM080FXVAGR/TK DB82-01330A
10 AM100FXVAGR/TK DB82-01331A
11 AM120FXVAGR/TK DB82-01332A
12 AM140FXVAGR/TK DB82-01333A
13 AM160FXVAGR/TK DB82-01334A
14 AM180FXVAGR/TK DB82-01335A
15 AM200FXVAGR/TK DB82-01336A
16 AM220FXVAGR/TK DB82-01337A

Table of Contents

Other manuals for Samsung AM160FNBFEB/EU

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Samsung AM160FNBFEB/EU and is the answer not in the manual?

Samsung AM160FNBFEB/EU Specifications

General IconGeneral
TypeAir conditioner indoor unit
Multi-split-
Product colorWhite
Gas hose diameter15.88 mm
Liquid hose diameter9.52 mm
Refrigerating mediumR410A
Air conditioner functionsHeating
Heating capacity (nominal)54600 BTU/h
Heating capacity in watts (max)16000 W
Cooling capacity in watts (nominal)- W
Operating temperature (heating) (T-T)-20 - 24 °C
AC input voltage220-240 V
Current (heating)14.3 A
AC input frequency50-60 Hz
Design load (cooling)- kW
Energy efficiency scaleA++ to G
Power consumption (heating) (max)3100 W
Hourly energy consumption (cooling)- kWh
Energy efficiency class (heating) (Average heating season)A++
Indoor unit typeWall-mountable
Indoor unit depth330 mm
Indoor unit width518 mm
Indoor unit height1210 mm
Indoor unit weight104000 g
Indoor units quantity1
Indoor unit package depth426 mm
Indoor unit package width652 mm
Indoor unit package height1289 mm
Indoor unit package weight107000 g
Indoor unit sound power level42 dB
Indoor unit noise level (high speed)60 dB
Outdoor unit noise level- dB

Related product manuals