EasyManuals Logo
Home>SICK>Accessories>DS35

SICK DS35 User Manual

SICK DS35
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
IO-Link interface
46 © SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
9.3.4 SICK-specic–teach
Index
decimal
(hex)
Description Format Access Value range Example Remarks
130 (0x82) TEACH UINT16 W 0: Q1 DtO (Q1 dis-
tance to object)
1: Q2 DtO (Q2 dis-
tance to object)
2: Q1 near
3: Q1 far
4: Q1 center
5: Q2 near
6: Q2 far
7: Q2 center
8: Q1 ObSB (Q1
object between
sensor and back-
ground)
9: Q2 ObSB (Q2
object between
sensor and back-
ground)
10: Q2 4 mA
11: Q2 20 mA
12: Q2 0 V
13: Q2 10 V
14: Q2 Analog
center
15: Fine teach
+10 mm
16: Fine teach
-10 mm
A teach overwrites
a function that has
already been set with
a newly selected func-
tion. For values that
are not taught in again
and for an unsuccess-
ful teach, the old value
is retained.
1) SICK-specic service data – teach

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK DS35 and is the answer not in the manual?

SICK DS35 Specifications

General IconGeneral
BrandSICK
ModelDS35
CategoryAccessories
LanguageEnglish

Related product manuals