EasyManuals Logo
Home>SICK>Accessories>DS35

SICK DS35 User Manual

SICK DS35
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
8014868/YIF1/2020-10-19 • © SICK AG • Subject to change without notice 59
Technical data
3) DT35-Bxxxxx, DS35-Bxxxxx: At 6% … 90% remission
DL35-Bxxxxx, DR35-Bxxxxx: on “diamond grade” reective tape
4) Depends on the congured speed "super-slow" … "super-fast"
5) Continuous change of the distance from the object in the measuring range
6) Lateral entry of the object into the measuring range
Table 23: Performance data
Outputrate,responsetime,andswitchingfrequencyasafunctionofthespeedsetting
All Dx35 except for DT35-B15551 and DS35-B15521
Super-fast Fast Medium Slow Super-slow
Output rate 1 ms 2 ms 4 ms 8 ms 32 ms
Response time 2.5 ms 6.5 ms 12.5 ms 24.5 ms 96.5 ms
Switching frequen-
cy
333 Hz 100 Hz 50 Hz 25 Hz 6 Hz
DT35-B15551 and DS35-B15521
Super-fast Fast Medium Slow Super-slow
Output rate 2 ms 4 ms 8 ms 16 ms 64 ms
Response time 4.5 ms 12.5 ms 24.5 ms 48.5 ms 192.5 ms
Switching frequen-
cy
166 Hz 50 Hz 25 Hz 12 Hz 3 Hz
Table 24: Overview of output rate, response time, and switching frequency
13.4 Supply
Supply voltage U
V
1)
12 V DC … 30 V DC
18 V DC … 30 V DC (when using IO-Link)
DT35-Bxxxxx, DL-Bxxxxx: 13 V DC ... 30 V DC
(when using the analog voltage output)
Power consumption
2)
≤ 1.7 W
Residual ripple
3)
< 5 V
SS
1) Limit values, reverse-polarity protected operation in short-circuit protected network: max. 8 A
2) At 20 °C and without load
3) May not fall short of or exceed U
v
tolerances
Table 25: Supply