Chapter 3
Communication Ports
RUGGEDCOM RX1501
Installation Guide
24 Serial Ports
Figure 38: 2 × T1/E1 with RJ45 Ports (TC2)
Figure 39: 2 × E1 with BNC Ports (E02)
The following is the pin-out for the BNC and RJ45 connectors:
Figure 40: RJ45 T1/E1 Pin Configuration
1. RTIP 2. TTIP 3. Chassis
Figure 41: RJ45C T1/E1 Pin Configuration
Pin Name Description
1 RRING Receive Negative
2 RTIP Receive Positive
3 Reserved (Do Not Connect)
4 TRING Transmit Negative
5 TTIP Transmit Positive
6 Reserved (Do Not Connect)
7 Reserved (Do Not Connect)
8 Reserved (Do Not Connect)
Section 3.5
Serial Ports
The RX1501 supports RJ45 serial ports, which can be run in RS232, RS485 or RS422 mode.
NOTE
On power-up, all serial ports default to RS485 mode. Each port can be individually set to RS232,
RS485 or RS422 mode through ROX II. For more information, refer to the ROX II User Guide for the
RX1501.
All serial ports feature an LED that indicates the current state of the port.