40 Gigabit Ethernet (1 Gbps) Optical Specifications
Mode
Connector
Type
Cable
Type (μm)
Tx λ (typ.)
(nm)
Tx min.
(dBm)
Tx max.
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.) (km)
Power
Budget
(dB)
MTRJ 62.5/125 -19 12
MM
LC 50/125
1300
-22.5
-14 -31 -14 2
8.5
LC 50/125 -22.5 8.5
SFP Fast Ethernet Transceivers
Mode
Connector
Type
Cable
Type (μm)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.) (km)
Power
Budget
(dB)
62.5/125 -20 11
MM LC
50/125
1310
-23.5
-14 -31 -14 2
7.5
62.5/125 -20 11
MM LC
50/125
1310
-23.5
-14 -31 -14 2
7.5
SM LC 9/125 1300 -15 -8 -31 -8 15 16
SM LC 9/125 1300 -15 -8 -31 -8 15 16
SM LC 9/125 1300 -5 0 -34 0 40 29
SM LC 9/125 1300 -5 0 -34 0 40 29
SM LC 9/125 1550 -5 0 -34 -10 80 29
SM LC 9/125 1550 -5 0 -34 -10 80 29
Section 4.5.2
Gigabit Ethernet (1 Gbps) Optical Specifications
NOTE
• Maximum segment length is greatly dependent on factors such as fiber quality, and the number
of patches and splices. Consult a Siemens sales associate when determining maximum segment
distances.
• All optical power numbers are listed as dBm averages.
• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
Fixed Gigabit Transceivers
Mode
Connector
Type
Cable
Type (μm)
Tx λ (typ.)
(nm)
Tx min
(dBm)
Tx max
(dBm)
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(typ.) (km)
Power
Budget
(dB)
MM LC 50/125 850 -9 -2.5 -20 0 0.5 11
SM SC 9/125 1310 -10 -3 -20 -3 10 10
SM LC 9/125 1310 -9.5 -3 -21 -3 10 11.5
SM SC 9/125 1310 -5 0 -20 -3 25 15