Installing and connecting the device
3.3 Connecting the device
SIMATIC IPC847D
42 Operating Instructions, 01/2014, A5E32997454-AA
3.3.3
Connecting the power supply
Note
The power supply contains
a PFC (Power Factor Correction) circuit to conform with the EMC
directive.
Uninterruptible AC power systems (UPSs) must supply a sinusoidal output voltage in the
normal and buffered mode when used with SIMATIC PCs with a PFC circuit.
UPS characteristics ar
e described and classified in the standards EN 50091-3 and IEC
62040
-3. Devices with sinusoidal output voltage in the normal and buffered mode are
identified with the classification "VFI
-SS-...." or "VI-SS-....".
Note
The wide
-range power supply module is designed for operation on 100 VAC to 240 VAC
mains.
The setting of the voltage range takes place automatically.
Localized information
Outside of the USA and Canada, operation on a 230 V power supply
:
This device is equipped with a safety-tested power cord which may only be connected to a
grounded shockproof power outlet. If you choose not to use this cable, you must use a
flexible cable of the following type: Cable cross-section at least 0.82 mm
2
and 15 A / 250 V
ground contact connector. The cable set must be compliant with the safety regulations of the
country where the device is to be installed and carry the identification labels required by law.
For the USA and Canada
:
For the United States and Canada, a CSA or UL-listed power cord must be used.
The connector must be compliant with NEMA 5-15.
120 V supply voltage
Use a flexible power cable with UL approval and CSA label which has the following features:
Type SJT with three leads, min. 18 AWG conductor cross-section, max. length 4.5 m,
parallel grounding plug 15 A, min. 125 V.
240 V supply voltage
Use a flexible cable with UL approval and CSA label which has the following features: Type
SJT with three conductors, min. 18 AWG conductor cross-section, max. length 4.5 m, and
tandem grounded connector 15 A, min. 250 V.

Table of Contents

Other manuals for Siemens SIMATIC IPC847D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC847D and is the answer not in the manual?

Siemens SIMATIC IPC847D Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC847D
CategoryIndustrial PC
LanguageEnglish

Related product manuals