Page #158 background image
Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
158 Configuration Manual, 10/2021, C79000-G8976-C475-03
Procedure
Follow the steps below to configure the IP address using the DHCP client ID:
1. Select the identification method in the "DHCP Mode" drop-down list.
If you select the DHCP mode "via DHCP Client ID" an input box appears.
In the enabled input box "DHCP client ID" enter a string to identify the device. This is
then evaluated by the DHCP server.
2. Select the "DHCP Client Configuration Request (Opt. 66, 67)", if you want the DHCP
client to use options 66 and 67 to download and then enable a configuration file.
3. Enable the "DHCP" option in the table.
4. Click the "Set Values" button.
Note
If a
configuration file is downloaded, this can trigger a system restart. If the currently
running configuration and the configuration in the downloaded configuration file
differ, the system restarts.
Make sure that the option "DHCP Client Configuration Request
(Opt. 66, 67)" is no
longer set.
4.4.8.2 DHCP Server
You can operate the device as a DHCP server. This allows IP addresses to be assigned
automatically to the connected devices. The IP addresses are either distributed
dynamically from an address band (pool) you have specified or a specific IP address is
assigned to a particular device.
On this page, specify the address band from which the device receives any IP address.
You configure the static assignment of the IP addresses in "Static Leases".
Requirement
The connected devices are configured so that they obtain the IP address from a
DHCP server.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
Product SeriesSC-600
VLAN SupportYes
VLAN standardIEEE 802.1Q
QoS SupportYes
Type of housingMetal
Product FamilySCALANCE
Product type designationSCALANCE SC-600
Port TypesEthernet
Number of 100/1000Base-SFP ports2
Operating Temperature-40°C to +60°C
Ambient temperature during operation-40 ... 60 °C
Ambient temperature during storage-40 ... 70 °C
Relative humidity during operation10% to 95% (non-condensing)
Protection class IPIP30
Power Supply24 V DC
Mounting TypeDIN rail
MTBFVaries by model
CertificationsCE, UL, cUL, ATEX, IECEx
Switching CapacityVaries by model
ThroughputVaries by model
MAC Address TableVaries by model
Number of VLANsVaries by model
Max. frame sizeVaries by model