Configuring with Web Based Management
4.7 "Security" menu
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
341
• Protocol
Specify the protocol for which the OpenVPN connection will be used.
• Proxy
Specify whether the OpenVPN tunnel to the defined client is established via a proxy
server. Only the proxy servers that you created in "System > Proxy Server" can be
selected.
4.7.7.4 Authentication
On this WBM page, you specify how the VPN connection partners authenticate
themselves with each other.
Description
The table contains the following columns:
• Name
Shows the name of the VPN connection to which the settings relate.
• TLS Auth. Key
Select the key file used to sign the TLS packets. If the incoming TLS packets are not
signed with this key, they are discarded.
• Method
Select the authentication method. For the VPN connection, it is essential that the
partner uses the same authentication method.
– Disabled
No authentication method is selected. Connection establishment is not possible.
– Certificates
Certificates are used for the authentication.
– User name / Password
The user name / password are used for the authentication.
– Cert/User Name/Password
For authentication, a user name and password are required in addition to the
certificate. The VPN connection is established only if both operations are
successful.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals