EasyManuals Logo
Home>Siemens>Switch>SIMATIC NET SCALANCE SC-600

Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Siemens SIMATIC NET SCALANCE SC-600
372 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
Technical basics
3.5 SNMP
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
43
3.5 SNMP
Introduction
With the aid of the Simple Network Management Protocol (SNMP), you monitor and
control network components from a central station, for example routers or switches.
SNMP controls the communication between the monitored devices and the monitoring
station.
Tasks of SNMP:
• Monitoring of network components
• Remote control and remote parameter assignment of network components
• Error detection and error notification
In versions v1 and v2c, SNMP has no security mechanisms. Each user in the network can
access data and also change parameter assignments using suitable software.
For the simple control of access rights without security aspects, community strings are
used.
The community string is transferred along with the query. If the community string is
correct, the SNMP agent responds and sends the requested data. If the community
string is not correct, the SNMP agent discards the query. Define different community
strings for read and write permissions. The community strings are transferred in plain
text.
Standard values of the community strings:
• public
has only read permissions
• private
has read and write permissions
Note
Because the SNMP community strings are used for access protection, do not use the
standard values "public" or "private". Change these values following the
initial
commissioning.
Further simple protection mechanisms at the device level:
• Allowed Host
The IP addresses of the monitoring systems are known to the monitored system.
• Read Only
If you assign "Read Only" to a monitored device, monitoring stations can only read out
data but cannot modify it.
SNMP data packets in versions v1 and v2c are not encrypted and can easily be read by
others.
The central station is also known as the management station. An SNMP agent is
installed on the devices to be monitored with which the management station exchanges
data.

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals