"Rule Set Assignment" area
• Type
Specify which rule set will be assigned to whom. The display of the following table
depends on the selection for "Type".
– Account
The rule set is activated through a local user account.
– Digital input
The rule set is executed by controlling the digital input. The prerequisite for this is
that the entry "Digital Input" is activated for the "Firewall" event under "System >
Events > Configuration".
– Radius Role
The rule set is activated through a RADIUS role.
– RADIUS User
The rule set is activated through a RADIUS user.
– Time triggered
Enforcement of the rule set is time-triggered.
The "User Account" table contains the following columns:
• Account
Only users with the remote access "only" or "additional" are displayed.
• Role
Shows the role of the user.
• Rule set
Define the rule set that is valid for this user.
• Combined with
Combines the user login with an event, e.g. the "Digital Input" event. To log in to the
WBM page for the dynamic firewall, voltage must be present at the digital input and
user login must be successful.
• Remaining Time
When this user is logged on, the remaining time for access is displayed.
• Force Deactivate
A user with administrator rights can log off the active user with this button.
The "Digital Input" table contains the following columns:
• Digital In
The available digital inputs.
• Rule set
Define the rule set that is controlled via the digital input.