Fundamental safety instructions
1.5 Residual risks of power drive systems
SINAMICS G120C converter
Getting Started, 04/2014, FW V4.7, A5E34264105B AA
13
1.5
Residual risks of power drive systems
The control and drive components of a drive system are approved for industrial and
commercial use in industrial line supplies. Their use in public line supplies requires a
different configuration and/or additional measures.
These components may only be operated in closed housings or in higher-level control
cabinets with protective covers that are closed, and when all of the protective devices are
used.
These components may only be handled by qualified and trained technical personnel who
are knowledgeable and observe all of the safety instructions on the components and in the
associated technical user documentation.
When assessing the machine's risk in accordance with the respective local regulations (e.g.,
EC Machinery Directive), the machine manufacturer must take into account the following
residual risks emanating from the control and drive components of a drive system:
1. Unintentional movements of driven machine components during commissioning,
operation, maintenance, and repairs caused by, for example,
Hardware and/or software errors in the sensors, control system, actuators, and cables
and connections
Response times of the control system and of the drive
Operation and/or environmental conditions outside the specification
Condensation/conductive contamination
Parameterization, programming, cabling, and installation errors
Use of wireless devices/mobile phones in the immediate vicinity of the control system
External influences/damage
2. In the event of a fault, exceptionally high temperatures, including an open fire, as well as
emissions of light, noise, particles, gases, etc. can occur inside and outside the inverter,
e.g.:
Component failure
Software errors
Operation and/or environmental conditions outside the specification
External influences/damage
Inverters of the Open Type/IP20 degree of protection must be installed in a metal control
cabinet (or protected by another equivalent measure) such that contact with fire inside
and outside the inverter is not possible.