- 38 -
6.4 Parallel I/O Wiring Example
When you connect a PLC, etc. to the CN5 parallel I/O connector, please use the I/O cable (LEC-CN5-#).
The wiring should be changed depending on the type of the parallel I/O (NPN or PNP).
Please wire referring to the following diagram.
NPN type PNP type
Parallel IO connector Parallel IO connector
Caution
24 VDC power supply for controller input and 24 VDC power supply for parallel I/O signal should be
separate supplies.
Parallel input/output
Signal power supply
24VDC
B12
ESTOP
B13
ALARM
B11
SVRE
B10
INP
B9
SETON
B8
AREA
B7
BUSY
B6
OUT5
B5
OUT4
B4
OUT3
B3
OUT2
B2
OUT1
B1
OUT0
A13
SVON
A12
RESET
A11
DRIVE
A10
HOLD
A9
SETUP
A8
IN5
A7
IN4
A6
IN3
A5
IN2
A4
IN1
A3
IN0
A2
COM
A1
COM
Parallel input/output
Signal power supply
24VDC
B12
ESTOP
B13
ALARM
B11
SVRE
B10
INP
B9
SETON
B8
AREA
B7
BUSY
B6
OUT5
B5
OUT4
B4
OUT3
B3
OUT2
B2
OUT1
B1
OUT0
A13
SVON
A12
RESET
A11
DRIVE
A10
HOLD
A9
SETUP
A8
IN5
A7
IN4
A6
IN3
A5
IN2
A4
IN1
A3
IN0
A2
COM
A1
COM
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks JXC61 and is the answer not in the manual?

SMC Networks JXC61 Specifications

General IconGeneral
BrandSMC Networks
ModelJXC61
CategoryController
LanguageEnglish

Related product manuals