- 63 -
The Controller
temperature
has exceeded
the
specification
(01-146)
Over
Temp.
D
RESET
SVON
Input
<Contents>
The temperature around the power element of the controller is
too high.
<Countermeasure>
Make improvements so that the temperature around the
controller is kept appropriate.
The Controller
supply voltage
is outside the
specification.
(01-147)
Control
power
error
D
RESET
SVON
Input
<Contents>
The control power supply voltage within the controller is out of a
range.
<Countermeasure>
Make sure that the voltage supplied to the control power
(C24V) of the controller is appropriate.
Caution
If one power supply is commonly used for the control power
and the motor power, or the power supply is inrush current
restraining type, a power voltage drop may be caused due to
a voltage drop during the acceleration/ deceleration.
The current
limit has been
exceeded
(01-148)
Over
load
D
RESET
SVON
Input
<Contents>
The output current accumulated value exceeds the specified
value.
<Countermeasure>
Check whether the movement of the electric actuator is
obstructed. Also confirm whether the electric actuator load,
speed, acceleration and deceleration are within the specification
range of the electric actuator.
Target position
(01-149)
Posn
failed
D
RESET
SVON
Input
<Contents>
Failed to reach to the set position within the set time limit.
<Countermeasure>
Eliminate any obstructions that interfere with the electric
actuator movement.
Also, make sure that the load, speed, acceleration and
deceleration are within the range of the electric actuators.
A
Communication
error occurred
(01-150)
Communi
cation
failure
D
RESET
SVON
Input
<Contents>
The connection with the higher-level devices is disconnected.
<Countermeasure>
Do not interrupt the connection between the PC and teaching
box when the electric actuator is being operated by upper-
level devices.
Absolute
encoder ID
does not match
controller data.
(01-153)
AbEnc
ID ALM
D
Turn ON
RESET,
SVON and
SETUP
<Contents> The controller detects the absolute encoder specific
No. when power is re-applied. This specific No. is different from
the number which has been connected before.
<Countermeasure> This alarm is generated when the product is
used for the first time, or when the actuator or controller is
replaced. Turn ON RESET to reset the alarm.