leave a gap of 40 mm or more with respect to the position where the magnet passes.
The motors of the electric actuator can be installed close to each other.
(2) Check whether there are any loose connections between the controller and actuator.
If contact failure occurs with the motor powerwiring, the motor power will be insufficient, which reduces
the holding force.
Because of this, the actuator moving part will fall downward in a vertical operation.
(In this operation, the lock function of the actuator with lock does not work).
The surge voltage generated by contact failure may damage the controller.
(3) The ambient temperature of the controller should be lower than 40℃ depending on the operating
conditions of the actuator.
For the LEY40 and LEYG40 series, if the vertical transfer load is greater than the weight listed below, the
controller must be used at an ambient temperature of 40
o
C or less. Otherwise, damage may occur due to
higher temperature of the controller.
LEY40#EA: 9 kg, LEY40#EB:19 kg, LEY40#EC:38 kg
LEYG40#EA:7 kg, LEYG40#EB:17 kg, LEYG40#EC:36 kg
Cution
(1) Supply power when the actuator is stationary.