FLIGHT MANUAL TSA-M, VARIANT S6
Doc.-No.: P400-006.000 E Page: 7-26 Revision: 1
Date of Issue: 07. October 2008 Date of Rev.: 28.01.2011
Red MAP-Warning-Light
OFF Engine is operated within allowed limits
ON
Operation above maximum-MAP, for procedures
see chapter 3
„Emergency Procedures“
FLASHING Take-off-
Power has been set for more than 5 minutes, for
procedures see chapter 3 „Emergency Procedures“
Caution: If the red MAP-warning-light is ON, IMMEDIATELY reduce
power!
7.11.5 Fire-Warning
The engine compartment of the STEMME S6 is equipped with a fire detecting
system which in case of an engine fire gives a clear warning signal by a red
warning light in combination with an acoustic alarm signal.
For fire detection 2 thermal sensors are mounted on the outside of the engine
fire wall above the carburators and another 2 sensors are mounted on the left
and right containment of the fire wall outlet and exhaust shaft.
The system is designed fail-safe, that means a possible cable break to the
sensors causes a fire-warning signal.
Red Fire-Warning light (Push-button)
Function In case of thermal sensors activation a fire-warning occurs by
permanent red light and acoustic alarm signal
Test Push the fire-warning button to check function, with pushing the
button the red light and the acoustic alarm signal has to work