7.13.6 Gauges and Indicator-Lights
Voltmeter
indicates the voltage at the main-bus
Ampèremeter indicates the electric-current drawn from the
battery (discharge) or flowing into the battery
(charge)
Internal-Generator-
Caution-Light (yellow)
The yellow light goes ON if the output-voltage of
the generator-controller is below the battery-
voltage (failure of the controller or the generator).
External-Alternator-
Warning-Light (red)
The red light goes ON if the output-voltage of the
belt-driven external-alternator falls below the
battery-voltage (failure of the external-alternator).