EasyManuals Logo

Sungrow SG20RT User Manual

Sungrow SG20RT
153 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
5
1.5 Maintenance Safety
Risk of inverter damage or personal injury due to incorrect service!
Before maintenance, disconnect the AC circuit breaker on the grid side and
then the DC switch. If a fault that may cause personal injury or device damage
is found before maintenance, disconnect the AC circuit breaker and wait until
the night before operating the DC switch. Otherwise, a fire inside the product or
an explosion may occur, causing personal injuries.
After the inverter is powered off for 10 minutes, measure the voltage and cur-
rent with professional instrument. Only when there is no voltage nor current
can operators who wear protective equipment operate and maintain the inverter.
Even if the inverter is shut down, it may still be hot and cause burns. Wear pro-
tective gloves before operating the inverter after it cools down.
Touching the power grid or the contact points and terminals on the inverter con-
nected to the power grid may lead to electric shock!
The power grid side may generate voltage. Always use a standard voltmeter to
ensure that there is no voltage before touching.
To prevent misuse or accidents caused by unrelated personnel, post prominent
warning signs or demarcate safety warning areas around the product.
To avoid the risk of electric shock, do not perform any other maintenance opera-
tions beyond those described in this manual. If necessary, contact your distributor
first. If the problem persists, contact SUNGROW. Otherwise, the losses caused is
not covered by the warranty.
User Manual 1 Safety Instructions

Table of Contents

Other manuals for Sungrow SG20RT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG20RT and is the answer not in the manual?

Sungrow SG20RT Specifications

General IconGeneral
ModelSG20RT
CategoryInverter
Max. DC Voltage1100 V
Rated AC Power Output20 kW
Max. Efficiency98.6%
Max. DC Input Power30 kW
Max. Input Voltage1100 V
Start Voltage200 V
Number of MPPTs2
Number of DC Inputs per MPPT2
Max. AC Apparent Power22 kVA
Rated Grid Frequency50 Hz / 60 Hz
Max. Output Current32 A
Power Factor at Rated Power>0.99
THDi<3%
DC SwitchYes
Protection ClassIP65
Cooling MethodNatural Convection
Protection DegreeIP65
Protection LevelIP65
MPPT Voltage Range200 V - 1000 V
Operating Temperature Range-25°C to +60°C
Input Voltage Range200 V - 1000 V
MPPT Range200 V - 1000 V
AC Voltage Range310 V - 480 V