7-12 MID UNIT
BONDING WIRE
Reattach bonding wire to driveshaft housing and tighten screw
securely.
POWER UNIT
1. Install power unit. (See page 6-9 to 6-11)
2. Tighten power unit mounting bolts and engine holder bolts
to specified torque.
" Power unit mounting bolt & Engine holder bolt :
8 mm 23 N
.
m (2.3 kg-m, 16.5 lb.-ft.)
10 mm 50 N
.
m (5.0 kg-m, 36.0 lb.-ft.)
3. Install lower mount covers to driveshaft housing, then tighten
lower mount cover bolts securely.