DF90/115/140 “K8” (’08) MODEL
18-27
TACHOMETER-MONITOR
DIGITAL DISPLAY SCREEN
The digital display screen can indicate the following engine infor-
mation.
1. Engine RPM
2. Engine Temperature
3. Engine operation hours
4. Atmospheric pressure
5. Fuel rate : Lit. or Gallons per hour
6. Intake manifold pressure
7. Trim Angle
8. Battery Voltage
9. Shift position
10. CAUTION name (When problem is detected)
11. Oil change reminder (When the total motor operating
hours have reached pre programmed hours)
12. Self-Diagnostic code (When problem is detected)
NOTE:
• The items of No. 1 – 8 can be selected by pressing “ENTER”
or / button. (For details, see Meter operation manual.)
Pressing “ENTER” or / button once changes the dis-
played data.
• When the ignition key is turned from OFF to ON:
• A caution buzzer will sound for two seconds.
• Two caution lamps also turns on for two seconds.
• The tachometer needle swings up then returns to zero (0)
rpm.
NOTE:
• The total operating hours displayed are those of actual engine
operation, not ignition switch “ON” time.
• The Caution information and Self-Diagnostic information
shown in the display screen can be deleted by pressing
“ENTER” button.
When more than one information occur at the same time,
press “ENTER” button to read the next information.
Even though deleting the information from the display screen,
both the caution lamp and buzzer remain on until the problems
have been solved.
Digital display screen
ENTER button
button
button