ELECTRICAL REQUIREMENTS
All Synesso™machines are rated to operate on 220v AC with a 50 or 60 Hz frequency, single phase. Machines
will operate between 208v and 240v.
Listed amp rangs are all measured at 220v. Incorrect voltage can cause malfuncon or damage to the ma-
chine.
An electrical socket and matching plug, rated at the proper voltage and amperage are required within three
feet of the machine. Plug ends are NOT included with the machine unless required by CSA or other cerca-
on.
Aach the plug end per manufacturer’s instrucons.
Make sure that the red electronics switch and the heang element breaker on the front of the electrical box
are in the OFF posion, then plug the power cord into the receptacle.
OPTIONAL: If recovery me is slow, install an In-Line Buck-Boost transformer to increase voltage below 208v
to opmize machine recovery me. Buck-boost transformers come in dierent sizes. Please choose the ap-
propriate one for your machine if required. 1 and 2 Group Machines require a 1.0 KVA transformer, 3 Group
Machines require a 1.5 KVA transformer.
SPECIAL ELECTRICAL INFORMATION FOR EMC-COMPLIANT MACHINES
(C-TICK FOR AUSTRALIA, CE FOR EUROPE AND OTHER LOCATIONS)
To comply with EMC (Electromagnec Compability) regulaons, Synesso™is required to install a capacitor
in the electronics box across the main power IN. To avoid an electric shock from the charge held in the ca-
pacitor, unplug the cord, taking care to NOT touch the metal prongs on the plug end. Turn the electronics
ON/OFF red rocker switch to the ON posion and wait a few seconds unl the red switch “goes dark.” At
that point, the electrical charge has dissipated.
North American Wire Color Worldwide Wire Color
Green Ground Green and Yellow Ground (Earth)
White 110v Line 1 Brown 220v
Black 110v Line 2 Blue Neutral
Model Cord Plug Rang (UL Listed) Machine Max Amp Draw
2 Group MVP 30 amp 28 amp
3 Group MVP 50 amp 36 amp
1 Group MVP Hydra 20 amp 16 amp
2 Group MVP Hydra 30 amp 30 amp
3 Group MVP Hydra 50 amp 40 amp