34
PROGRAMMING
Line 1 of the rst brew group control screen indicates the current temperature of the brew tank as measured
by its probe. Once this temperature reaches the set point, it will connuously cycle up and down by small
increments as the electronics balance the temperature. This line also indicates the acve program (PRG1 in
this case). Changing the acve program will update the sengs on lines below.
Line 2 is indicang the set point of 202.0F (94.4C).
Line 3 indicates the length of me pre-infusion is set for in the current program. When starng a shot in MP
or VP mode, pre-infusion will allow line pressure water to soak the puck for as long as indicated before mov-
ing on to the next brew phase. Seng the pre-infusion me down to 0.0 seconds will skip the pre-infusion
phase in MP and VP modes. One step lower than 0.0 is the “MAN” seng, which will require the operator to
exit the pre-infusion phase manually in MP mode, and will skip pre-infusion in VP mode.
Line 4 indicates the length me set for the ramp-up phase in the current program. This opon will ONLY be
visible on MVP Hydra models. Ramp-up me begins once the pre-infusion stage has nished.
To cycle to the next display screen, press the down buon.
Menu Level 1: Group 1, Program 1
Factory Sengs:
The factory sengs for your machine are as follows:
Brew Group Temperature 203°F
Steam Tank Temperature 250°F
Brew Mode M (Manual)
Right-Hold Save Lockout Locked (To Unlock refer to page 45)
Enabled Programs 1 & 2 Enabled (3-6 Disabled)
Temperature Units Fahrenheit
Program 1: Program 2:
Pre-Infusion 4 seconds Pre-Infusion 4 seconds
Ramp Up 2 seconds Ramp Up 2 seconds
Ramp Down 92% Ramp Down 92%
Total Water Count 280 Total Water Count 380