61
Diuser screen/screw, or jet is clogged
Soap residue not fully ushed aer cleaning has glued the valve closed (tap the valve body gently).
Brew solenoid has been sealed shut by dried soap or has failed.
Brew Gauge
Brew Pressure gauge needle value changes oen:
This is normal. The lowest number (usually 3-5 bar) reects the incoming line pressure. When brewing
the needle reects brew pressure (8.5-9 bar). When the brew tanks heat, the water expands and the ex-
pansion valve relieves the pressure at 11 or 12 Bar.
Brew Pressure is Low:
Check pump to make sure pressure is properly set
Water supply hose to the pump is kinked
Water lter is plugged. Check and replace if necessary
Pump Motor Runs; No Brew Pressure:
Failed pump, needs to be replaced
Brew Solenoid is stuck (can be caused by soap residue not fully ushed aer cleaning).
Brew Solenoid has failed
The line between the pump and the water supply has collapsed or is kinked
Hose to the pump is kinked
Water lter is plugged. Check and replace if necessary
Water supply is inadequate
Readout for Brew Water Temperature Varies by a Few Degrees:
The control must “see” the increment just above the set point before it sends a signal to turn o the
heang element. This will allow the electronics to show a reading just above the set point. The energy
from the heang element and the tube for the preheated incoming water are within 1” or 25mm from
the locaon of the temperature sensing probe in the coee tank. The water pick up tube for brew water
is at the top of the brew group and is in the most temperature stable water in the tank. Meaning, the
readout can show a temperature of a few degrees above your set point, and may uctuate due to the
heat from the element or heat exchanger, but your brew water is actually at the set point.
Electronics
All zones read LOW:
Check to make sure the element breaker is ON (element switch is to the le). Zones will read low unl
the temperature in that zone reaches 175° F. Please allow 20-30 minutes to heat up inially.
TROUBLESHOOTING