188
OPTIONS
Second Auxiliary Hydraulics
Second Auxiliary Hydraulic Lines
WARNING
Oil may spurt out if caps or filters are
removed or pipes disconnected before
releasing the pressure in the hydraulic
system.
When disconnecting hoses, release the
internal pressure before removing.
These lines deliver the hydraulic oil necessary
for operating a hydraulic attachment.
Stop valve ......
: Closed : Open
Connecting the Hydraulic Circuits
To connect the attachment hydraulic lines,
use the following procedures:
1. Release the pressure remaining in the lines
then close the stop valve.
Refer to Releasing the residual
pressure.
2. Remove the plugs.
3. Connect the attachment hydraulic lines to
ports (c) and (d).
4. Open the stop valves.
5. When connecting is complete, purge air
from the hydraulic lines.
a. Start and run the engine at low idle with
no load for 10 minutes.
b. With the engine running at low idle
operate the auxiliary hydraulic switches
repeatedly (approx. 10 times) to purge
air from the hydraulic lines.
c. Stop the engine and wait for more than
5 minutes until bubbles escape from the
hydraulic oil in the tank.
IMPORTANT: Follow the procedures for
purging air as instructed by the attachment
manufacturer if specied to do so.
6. Check for leaks.