HDLG7 HD Dual Link Video Generator module remote commands
Command examp
les
This section shows some examples of using remote commands to generate dual
link signals and to set the timing offset of the LINK B outputs.
Generating d
ual link
signals from converted
input
To output dual link signals from a converted input where the source test s ignal is
1080 59.94i standard, 100% Color Bars from the HDVG7 module in slot 4. The
HDLG7 module is in slot 3, the sampling structure is "GBR 4:4:4 10 bits," and
alpha chan
nel data o f 10% Flat Field is inserted:
INST:SEL "HDVG7:4"
INST: NSEL 4;:MMEM:LOAD:SIGN 4,"/1 080 59.94i/COLOR
BAR/100%^Color Bars"
INST:SEL "HDLG7:3"
OUTP1:SYNT:STAT OFF
OUTP1:
SAMP:SEL GBR444A_10B
OUTP1:ALPH FF_10P
Gener
ating synthesized
dual link signals
To generate dual link signals where the HDLG7 module is in slot 3, the video
standard is 1080 59.94i, the test signal is 100% Color Bars, the sampling structure
is "1080 YCbCr 4:4:4 10 bits," and no alpha channel data is inserted:
INST:SEL "HDLG7:3"
OUTP1:SYNT:STAT ON
OUTP1:STAN HD1080_59I
OUTP1:SYNT:SIGN COLBAR_100P
O
UTP1:SAMP:SEL YCB444_10B
Generating synthesized
projector test patterns
To generate projector test patterns where the video standard is 2K 1080 24p and
t
he test pattern is Black to Gray Step-8:
OUTP1:STAN TK1080_24P
OUTP1:SYNT:CINE:COLO PROJ
OUTP1:SYNT:CINE:PROJ 25
You can list all the projector test patterns and their numbers by using the :OUTP1:
SYNT:CINE:PROJ:CAT? command.
Draft
TG8000 Multiformat Test Signal Generator Programmer Manual 133