AWVG7 Analog Wideband Video Generator module remote commands
Returns the cur
rent state of the random scrolling mode.
:OUTPut1:VIDeo:SYNC:STATe ON |OFF
Sets whether or not a sync signal is multiplexed with the B and R signals when
a GBR signal is being output. You can also use 1 or 0 instead of ON or OFF.
:OUTPut1:VIDeo:SYNC:STATe ?
Returns whether or not a sync signal is mul
tiplexed with the B and R signals
when a GBR signal is being output.
SENSE commands
Use these commands to set the timing offset of the output signals relative to the
internal reference signal (frame reset signal).
Refer to Operating Basics in the TG8000 User Manual for detailed information
about the setting range.
Command tree
:SENSe<n>
:CORRection
:MDELay
:HORizontal <numeric_value>
:STEP
<numeric_v
alue>
:VERTical <numeric_value>
:STEP
<numeric_value>
Command d escription
:SENSe1:CORRection:MDELay :HORizontal <numeric_value>
Sets the horizontal timing o ffset of the output signals. The timing resolution
is clock-cycles. The units are microseconds. You can use UP, DOWN, or
DEF instead of the numeric value. See page 2-2 for additional detail on UP,
DOWN, and DEF. If the argument exceeds the horizontal time value, then the
vertical offset is adjusted to ac commodate the requested delay.
:SENSe1:CORRection:MDELay :HORizontal?
Returns the current horizontal timing offset of the output signals.
:SENSe1:CORRection:MDELay :HORizontal:STEP <numeric_value>
Sets the step increment used by the UP o r DOWN commands. The units are
microseconds. You can use MIN, MAX, or DEF instead of a numeric value.
:SENSe1:CORRection:MDELay :HORizontal:STEP?
Returns the current step increment.
Draft