BG7 Black Generator module remote commands
Sets the vertic
al timing offset of a specific BLACK output. The argument can
be a floating point value that is translated into integer lines with a horizontal
offset. You can use UP, DOWN, or DEF instead of a numeric value. The <n>
in the command represents the connector number. You can use a ny connector
number from 1 through 4.
:SENSe<n>:CORRection:MDEL ay:VERTical?
Returns the vertical timing offset of a specific B LACK output. The <n> in
the command represents the connector number. You can use any connector
number from 1 through 4.
:SENSe<n>:CORRection:MDEL ay:VERTical:STEP <numeric_value>
Sets the step increment used by the UP or DOWN commands. You can use
MIN, MAX, or DEF instead of the numeric values. The <n> in the command
represents the connector number. You can use any connector number from
1through4.
:SENSe<n>:CORRection:MDEL ay:VERTical:STEP?
Returns the step increment used by the UP or DOWN commands. The <n> in
the command represents the connector number. You can use any connector
number from 1 through 4.
Draft
64 TG8000 Multiformat Test Signal Generator Programmer Manual