Specifications
Table 34: Signal level and cable length detector characteristics (cont.)
Characteristic Performance requirement Reference information
Cable Loss Measurement
Displays loss near 160 MHz minus loss near
18 MHz.
Not a function of the selected cable type. You
can set alarm threshold without knowing the
cable type if you characterize the receiver.
Cable Types
United States SD/HD Belden 1505A, 1506A, 1694A,
1695A, 1855A, and 8281.
Japan
Canare L-5CFB
Europe Image 1000
Audio Option AD
Option AD (Digital/Analog Audio) is available for the WVR6020, WVR7020, and
WVR712
0. The following tables list the the characteristics specific to Option AD.
Table 35: Audio bar displays (Option AD)
Characteristic Performance requirement Reference information
Modes
The user may configure the response
dynamics (ballistics), reference levels,
peak hold, offset, and scale of the meters
to suit the monitoring needs of the
particular installation or situation. Each
pair has a phase correlation meter.
Pair Mode Any 4 channel pairs with phase correlation
meters.
Surround Mode Left, Right, Center,
Low-frequency-effects, Left-surround,
Right-surround meters, and an extra
channel pair. Phase correlation meters
between the two left- right-pairs and the
extra pair.
Audio Sources Selected from AES A inputs, AES B
inputs embedded audio.
Level Meter Resolution
0.056 dB steps at 30 dB scale, for from
full scale to –20 dB FS.
0.20 dB Steps at 0 to –70 dB scale, for
signals above –20 dB FS, Tiled display.
22 Waveform Rasterizers Specifications and Performance Verification