Specications
Alarms
The tables in this section provide a list of all the WVR6020, WVR7020, and
WVR7120 alarms.
Table 45: Common alarms (WVR6020, WVR7020, and WVR7120)
Alarm Indication
HW Fault
A system fault occurred. May require service.
SDI Input Missing No signal is detected on the selected SDI input.
SDI Input Signal Lock Unable to lock to selected SDI input signal.
Reference Missing No signal is detected on the Ref input when REF EXT is selected.
Ref Lock Unable to lock to the Ref input signal when REF EXT is selected.
Ref F mt Mismatch The signal format detected on Ref input differs from the congured External Ref format.
RGB Gamut Error The selected video input signal contains colors that violate the congured Diamond gamut
thresh
olds.
Compos
ite Gamut Error
The sel
ected video input signal contains colors that violate the congured Arrowhead gamut
thresholds.
Luma Gamut Error The selected video input signal contains luminance levels that violate the congured Luma
gamut thresholds.
Video Fmt Change A change occurred in the format of the selected video input signal.
Video Fmt Mismatch
The s ignal format detected on the selected video input differs from the congured Input
For
mat or that the format detected differs from that indicated by the signal’s SMPTE 352
payload identier.
Vid/Ref M ismatch The Ref signal format is not compatible with the Input signal format.
(See page 33, Signal Input-to-Reference Compatibility Tables.)
Line Length Error
The length of a video line differs from that expected for the detected video format.
Field Length Error
The length of a video eld differs from that expected for the detected video format.
EAV Place Error
The location of the EAV timing reference signal differs from that expected for the detected
v
ideo format.
SAV Place Error The location of the SAV timing reference signal differs from that expected for the detected
video format.
Timecode Vitc Missing
A break or discontinuity in the VITC has occurred.
Timecode Vitc Invalid
The VITC was lost for one frame but has reappeared.
Timecode Ltc Missing
A break or discontinuity in the LTC has occurred.
Timecode Ltc Invalid
The LTC was lost for one frame but has reappeared.
Timecode Anc Missing
A break or discontinuity in the ANC timecode has occurred.
Timecode Anc Invalid
The ANC timecode was lost for one frame but has reappeared.
Closed Caption Missing The congured Closed Caption Transport stream or streams are not present in the selected
video input signal.
CC Service(s) Missing One or more congured EIA 608 Required Services is not present in the closed caption
data stream.
30 Waveform Rasterizers Specications and Performance Verication

Table of Contents

Other manuals for Tektronix WVR6020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix WVR6020 and is the answer not in the manual?

Tektronix WVR6020 Specifications

General IconGeneral
BrandTektronix
ModelWVR6020
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals