Video and General Performance Verification
Video and Gene
ral Performance Verification
This perform
ance verification section includes procedures that verify both
standard and option-equipped instruments.
Required Equipment
Table 63: Required test equipment for performance verification
Test equipment Requirements Exam ple
XGA Monitor Computer monitor capable of 1024 x 768
x60Hzscanrate
NTSC Black Tektronix TG2000 with BG1 and additional
modules indicated below.
1080i 59.94 HD signals required for HD
capable instruments:
100% color bars
10-bit shallow r amp
SDI Matrix Split Field Pathological
Signal
100% sweep
HDVG1 module for TG2000 (Embedded
audio needed for audio options DG, AD,
DS, DDE)
HD signal with adjustable SDI amplitude
required for HD capable instruments
HDST1 module for TG2000
1080i 59.94 analog tri-level sync required
for HD capable instruments
AWVG1 module for TG2000
5225/270 SD signals required SD capable
instruments:
100% color bars
10-bit shallow r amp
SDI Matrix Pathological Signal
100% sweep
Adjustable SDI amplitude
DVG1 with option S1 module for TG2000
(Embedded audio needed for audio
options DG, AD, DS, DDE)
Composite signals required for CPS
capable instruments: NTSC SMPTE bars
AVG1 module for TG2000
SDI serial digital video test generator with
embedded audio and composite signal
source
Precision calibration signals for CPS
capable instruments
AVC1 module for TG2000
1
HD Cable-clone cable simulator Simulate 10 to 150 meters of 8281
equivalent in 10 m steps.
Faraday FFC Kit
SD Cable-clone cable simulator Simulate 0 to 400 meters of 8281
equivalent in 25 meter steps.
Faraday SC75A800B-G
Waveform Rasterizers Specifications and Performance Verification 7 3