Table 63: Required test equipment for performance verication (cont.)
Test equipment R equirements E xample
75 coaxial cables
(3 required)
General purpose digital video
Male-to-male BNC connectors 1 or
2 meters long
Belden 8281.
Tektronix part number: 012-0159-00 or
012-0159-01
75 terminator for Analog Video
Male connector, Precision Tektronix part number: 011-0102-03
75 terminator for SDI signal (2)
Male, wideband Tektronix part number: 011-0163-00
75 network analyzer or
Spectrum Analyzer with Tracking
Generator
75 test port; 50 input and output test
ports
Agilent 8712 75
Tektronix 2712
Wide Band Engineering A57TUC with
male 75 BNC test port
75 calibration kit Maury 8580A 75 BNC
VITC Generator (Required for SD and
Option CPS)
Horita VG-50 or Adrienne AEC-Box-28
LTC generator Horita TG-50 or Adrienne AEC-Box-28
NTSC to SDI Converter (Required for SD) Grass Valley 8960DEC or AJA model
D5D
RCA and BNC to 15 pin header custom
cable
Cable description:
15-pin male Dsub connector;
Tektronix part number 131-1164-00
BNC; Tektronix part number
131-5647-00
RCA plug; Allied 932-1098
Wire
(See Figure 1.)
Square Wave generator 10 kHz, 5 V output, 50 output
impedance
Tektronix FG5010
1 to 2 VDC voltage source (Required for
Option CPS)
1.5 V battery or power supply
BNC to retractable hook tip (Required for
Option CPS)
Tektronix part number: 013-0076-01
RF Generator (Required for Option EYE
or PHY)
50 kHz to 2.5 GHz sinewave for checking
eye signal bandwidth
Rhode & Schwarz SMT03
RF Power Meter with 75 head 50 MHz to 2 GHz Used to characterize
RF generator for checking eye signal
bandwidth
Agilent E4418B Power Meter with 8483A
Power Sensor
Wideband 50 to 75 matching pad 0 to 2.5 GHz, N connectors,
75 N-to-BNC adapter
Rhode & Schwarz RAM
1
Note that the AVC1 is not available outside of Tektronix. Other equipment can be substituted but it might not have sufcient accuracy to guarantee the
specications. For Hum insertion, a general-purpose sine wave generator can be used to terminate and drive back into the video signal through appropriate
impedance matching.
74 Waveform Rasterizers Specications and Performance Verication

Table of Contents

Other manuals for Tektronix WVR6020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix WVR6020 and is the answer not in the manual?

Tektronix WVR6020 Specifications

General IconGeneral
BrandTektronix
ModelWVR6020
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals