17
Decalcification
Risk of damage in frost conditions.
In frost conditions, ambient temperatures be-
low 39 °F (4 °C), there is a risk that water in
pipes, faucets and appliances could freeze.
This can cause considerable damage.
• Do not decalcify the appliance in frost con-
ditions.
Decalcification frequency
Lime scale occurs especially as a result of
precipitation from “hard” water. The appliance
must be decalcified regularly depending on wa-
ter hardness and hot water consumption.
Recommended decalcification frequency
per year
Water hardness
mg/l CaCO
3
Very hard
>180
1 2 4
Hard
121 – 180
1 1 3
Moderately
hard
61 – 120
1 1 2
Soft
0 – 60
1 1 1
Use* low normal high
* Hot water consumption (approximately)
low 635 gallons/year 2400 l/year
normal 1585 gallons/year 6000 l/year
high 6350 gallons/year 24000 l/year
Decalcification (models without
control panel)
Models AquaGo basic without control panel:
You can have these models decalcified by
a Truma service partner. Please contact the
following address:
Truma Corp.
2800 Harman Drive
Elkhart, IN 46514
USA
Toll Free 1-855-558-7862
Fax 1-574-538-2426
info@trumacorp.com
www.truma.net
Refer to “Decalcification frequency” on
page17 for the decalcification frequency.
Decalcification (models with
control panel)
AquaGo comfort / AquaGo comfort plus
with control panel (included with delivery).
An integrated water consumption meter rec-
ognizes (after hot water consumption of ap-
prox. 1585 gallons / 6000 l) that decalcification
is necessary. The assumed water hardness is
“hard” and cannot be changed. The yellow
status LED3 (Fig. 9) indicates that decalcifica-
tion is necessary (goes off briefly about every
7 seconds).