Programable DC Electronic Load User Manual
27
Figure 4-2-2 Setting Interface of List Mode
List value Description
Protocol
QC2.0/QC3.0/QC4.0
/PD3.0/BC1.2
Select the fast charge charger protocol supported
by the tested power supply. Protocol BC1.2 and
single mode DPDN are the same function.
(UTL8511C)
QC value
Set the voltage point
supported by the fast
charge charger
The fast charge charger supports different
protocols, and the supported voltage range is
different. The system will limit when setting the
value. (UTL8511C)
Mode
CC/CV/CR/CP/Open
/Short
Select the load mode of current steps
Value
Set the fixed value of
the set mode
Set the fixed value of the mode, the default value
of Open/Short is 1
Time 200~999999ms
Set the load execution time of each step, any time
between 200~999999ms can be selected
Check
Off/Curr/Volt/Power/
VPP/IPP/D+/D-
Select check items
Min
Lower limit of check
items
Set the lower limit of check items
Max
Upper limit of check
items
Set the upper limit of check items
4.2.2.1 Parameter Setting in List Mode
In the setting interface of list mode, the upper area is used to set the list group number
and other parameters, as shown in the following table 4-2-2-1.
Table 4-2-2-1 Parameter Setting in List Mode