UAD Powered Plug-Ins Manual - 43 - Chapter 2: Ampex ATR-102
Manual Calibration Notes
0 dB on the output meter represents +4 dBm (and –12 dBFS digital) when
Reproduce is in its calibrated position, which is marked with the “red arrow
sticker.”
For proper calibration, follow the entire calibration procedure in order.
This example uses 3.5 dB overbias. The amount of gain reduction in step 12
determines the amount of overbias. In some cases we used more than
3.5 dB of overbias to achieve a flatter response.
Generally speaking, higher Cal Level values will have higher Distortion
Meter values for a given reading on the Meters. If Bias is set very low, dis-
tortion may increase at lower Cal Levels.
We recommend leaving the record SHELF EQ control in its default position.
The Ampex ATR-102 hardware has an additional gain control via a set-
screw (like Repro HF/LF, Bias, etc) which is usually used for manual gain
calibrations. This control is not available in the plug-in because it would be
redundant – the Reproduce control performs the same function.
We chose to calibrate our reference machine using MRL fringing-compen-
sated calibration tapes, without later adjusting the Repro LF EQ for unity
gain using external test tones. Therefore the calibrated values in the plug-in
reflect this alignment method. In-depth discussions about fringing compen-
sation and system alignment are beyond the scope of this manual; thorough
resources are available from the MRL website at: http://www.mrltapes.com
Tape Type 111 uses a calibration level of 0 dB. This value is not available
in the plug-in, but it can be emulated by setting the CAL level to +3 dB, then
reducing the input level (Record knob) by –3 dB and increasing the output
level (Reproduce knob) by +3 dB.
The plug-in operates at an internal level of –12 dBFS. Therefore a digital sig-
nal with a level of –12 dB below full scale digital (0 dBFS) at the plug-in in-
put will represent 0 dB on the plug-in meters (if the plug-in is calibrated).
The included artist presets demonstrate how manual calibration can be
used to obtain sonic variations (see “Artist Presets” on page 23).
Tip: For easy recall in future sessions, save unique calibrations as a preset.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Universal Audio Ampex ATR-102 and is the answer not in the manual?

Universal Audio Ampex ATR-102 Specifications

General IconGeneral
BrandUniversal Audio
ModelAmpex ATR-102
CategoryRecording Equipment
LanguageEnglish

Related product manuals