All rights reserved 63 Servicemanual_UR10_en_3.1.3
3.2.8 Replacement of current distributor
Take care of ESD handling 3.2.1 Handling ESD-sensitive parts
How to replace current distributor in Controller box
Note: use the same procedure for power down and removing the aluminum cover plate
and cables for teach pendant as in chapter 3.2.5 Replacement of teach pendant
1. Current distributor is placed on top of rack.
2. Before dismounting the current distributor, mark and disconnect the cables from the circuit board.
3. Replace current distributor with new one.
4. Reconnect the wires for the current distributor.
5. Re-install Controller module in reverse order and connect the 2 wires for the fan and cables for the
teach pendant.
6. Carefully put back the grey aluminum cover plate, make sure to mount it correct and fix it with the
5 screws.
7. Connect power and verify that teach pendant works properly.