Valent Controls IOM 8 IOM-C1-0616
Part Number 474626
5. If an existing event is selected, the SELECT
EVENT menu appears. Press Enter to edit
the event or to underline the DELETE
EVENT menu option. Press Enter to delete
the event from the current schedule.
SELECT EVENT
EDIT EVENT 1 - 8:00 AM
DELETE EVENT 1
BACK
6. The event menu is identical whether editing
an existing event or creating a new event.
Use ▲ and ▼ to select the desired field and
press Enter to change its value. Press
Enter to complete the change.
MONDAY EVENT
START TIME: 8:00 AM
END TIME: 10:00 AM
VALUE: OCCUPIED
MENU SAVE CANC
7. To temporarily disable an event, change the
Value field from OCCUPIED to UNOCCUPIED.
MONDAY EVENT
START TIME: 8:00 AM
END TIME: 10:00 AM
VALUE: UNOCCUPIED
MENU SAVE CANC
8. Press SAVE to save the settings in the
controller.
Any request for occupancy from the push button
on a space temperature sensor will be effective
for two hours.
Changing the IP Address
The local display may be used to change the
default network settings of the controller.
WARNING:
Setting the IP address to an incorrect value may
cause the controller to lock up and may require
replacing the controller. Make sure the IP
address, gateway, and subnet mask are set
correctly before saving the new settings.
The controller ships with the following default
settings:
JENESYS TCP/IP SETTINGS
IP ADDRESS: 192.168. 1.101
SUBNETMASK: 255.255.255. 0
GATEWAY: 192.168. 1. 1
MENU SAVE
1. Push any button on the LCD interface to
refresh the display. If the main menu is not
shown, press the MENU button to return to the
main menu.
2. Press to move the underline cursor to
SYSTEM SETTINGS and press Enter.
Valent LCD Interface
POINTS
SCHEDULING
SYSTEM SETTINGS
3. Press Enter to select SET TCP/IP
SETTINGS.
JENESYS SYSTEM SETTINGS
SET TCP/IP SETTINGS
SYS DATE: AUG 17, 2012
SYS TIME: 15:02
TIMEZONE: AMERICA/CHICA
(-5/-6)
MENU CANC